Enabling PXE Booting on Integrated PC Modules

Enabling PXE Booting on Integrated PC Modules

 This guide will cover the process of enabling Network (PXE) booting on Clear Touch Interactive PC Modules.  To begin, power on the panel and switch the input to "PC".  While the PC is booting, rapidly press "F2" using your remote control or an external keyboard to enter the BIOS settings.  Use your arrow keys to navigate to the "Boot" menu and change the "Launch PXE OpROM policy" to "UEFI Only."
                                                                                                                                                                               BIOS "Boot" Options

Press "F10" on your remote or keyboard to save changes and restart the PC.  Next, rapidly press "F7" on startup to enter the Boot Menu.  Select the PC's gigabit network adapter that you wish to boot from (in this example, Realtek PXE B01 D00).

                                                                                                                                                           Boot Menu

    • Related Articles

    • Built in PC - Audio Issues within Windows

      Related Product(s): All PC Modules  Issue Description: Audio does not work as there is an incorrect audio driver loaded. Issue Resolution: Go into Device Manager, update drives and/or uninstall the audio drivers listed, reboot the PC and Windows will ...
    • Installing Windows 11 on a Clear Touch Interactive PC Module

      Clear Touch Interactive offers a range of Integrated PC Modules that can either be purchased pre-loaded with Windows 10 Pro or without an operating system.  If you or your organization chooses to purchase your PC Module without an OS, you will need ...
    • Installing Windows 10 on a Clear Touch Interactive PC Module

      Clear Touch Interactive offers a range of Integrated PC Modules that can either be purchased pre-loaded with Windows 10 Pro or without an operating system.  If you or your organization chooses to purchase your PC Module without an OS, you will need ...
    • How to Calibrate Touch on Internal PC Module (Windows 10)

      How to Calibrate Touch on your Clear Touch Internal PC Module (Windows 10) 1. Go to the white Search Bar in the lower left corner of your Desktop. Click it and type "Control Panel." When Control Panel pops up in the right menu, click it. 2. When the ...
    • Fix for Clear Touch Interactive PC Module Shutting Down Using Streaming Services.

      The following fix will apply to panels of the following series: 6000U, 6000K, 6000K+, 8086MAX, 7000X, and 7000XE. If you have experienced your Clear Touch Interactive PC module shutting down and/or going to a black screen and displaying "No Signal" ...